Need Help? Call 603-669-6427  
   CED   
View Cart CART  
 Shop by Category  ( Show All )

Back

Top Sellers in Distribution Equipt - Safety Switches

   
Show  items per page    First Previous  Page   of  6  Next Last
EQUIPMENT GROUNDING KIT
SQUARE D/TELEMECANIQUE
GTK03
SERVICE GROUND KIT
EQUIPMENT GROUND KIT; SWITCH CURRENT RATING 60 AMPERE; WIRE SIZE (2) 10 AWG (ALUMINUM), (2) 12 AWG (COPPER), (1) 4 AWG (ALUMINUM/COPPER); USED ON GENERAL DUTY SAFETY SWITCH

Show all:  Safety Switch Accessories

 Spec Sheet   |   More Details
IN STOCK
SERVICE GROUND KIT
SQUARE D/TELEMECANIQUE
PKOGTA2
GRND BAR KIT
SERVICE GROUND KIT; SWITCH CURRENT RATING 400 AMPERE; WIRE SIZE (4) 10 TO 2/0 AWG (COPPER), (4) 6 TO 2/0 AWG (ALUMINUM); USED ON GENERAL DUTY SAFETY SWITCH

Show all:  Safety Switch Accessories

 Spec Sheet   |   More Details
IN STOCK
SAFETY SWITCH
SQUARE D/TELEMECANIQUE
HU361
30A-600V-3P SW
HEAVY DUTY SAFETY; 600 V AC VOLTAGE; 250/600 V DC VOLTAGE; 30 AMPERE CURRENT RATING; POWER RATING 5 HP AT 240 VAC 1 PHASE, 10 HP AT 240 VAC 3 PHASE, 7 1/2 HP AT 480 VAC 1 PHASE, 20 HP AT 480 VAC 3 PHASE, 10 HP AT 600 VAC 1 PHASE, 30 HP AT 600 VAC 3 PHASE (MAXIMUM); 5 HP AT 250 VDC, 15 HP AT 600 VDC; 3 POLE; 3 WIRE; NON FUSIBLE FUSE; SOLID NEUTRAL; NEMA 1 ENCLOSURE; STEEL ENCLOSURE; SIZE 7.55 INCH W X 4.88 INCH D X 14.6 INCH H; APPROVAL UL, CSA; HU MODEL

Show all:  Non-Fusible Heavy Duty Safety Switches

 Spec Sheet   |   More Details
IN STOCK
EQUIPMENT GROUNDING KIT
SQUARE D/TELEMECANIQUE
GTK0610
GROUND KIT
EQUIPMENT GROUND KIT; SWITCH CURRENT RATING 100 AMPERE; WIRE SIZE (2) 2/0 AWG (ALUMINUM/COPPER); USED ON GENERAL DUTY SAFETY SWITCH

Show all:  Safety Switch Accessories

 Spec Sheet   |   More Details
IN STOCK
GROUND BAR KIT
SQUARE D/TELEMECANIQUE
PK3GTA1
GRNDG BAR KIT
CONDUCTOR MATERIAL COPPER/ALUMINUM; 3 TERMINAL (12 TO 10 AWG ALUMINUM, 14 TO 10 AWG COPPER); USED ON QO[R] LOAD CENTER

Show all:  Safety Switch Accessories

 Spec Sheet   |   More Details
IN STOCK
SAFETY SWITCH
SQUARE D/TELEMECANIQUE
H361
30A-600V-3P SW
HEAVY DUTY SAFETY; 600 V AC VOLTAGE; 250/600 V DC VOLTAGE; 30 AMPERE CURRENT RATING; POWER RATING 3 HP AT 480 VAC 1 PHASE, 5 HP AT 480 VAC 3 PHASE, 7 1/2 HP AT 600 VAC 3 PHASE (STANDARD); 7 1/2 HP AT 480 VAC 1 PHASE, 15 HP AT 480 VAC 3 PHASE, 20 HP AT 600 VAC 3 PHASE (MAXIMUM); 5 HP AT 250 VDC, 15 HP AT 600 VDC; 3 POLE; 3 WIRE; CLASS R FUSE; FUSIBLE FUSE; SOLID NEUTRAL; NEMA 1 ENCLOSURE; STEEL ENCLOSURE; SIZE 7.55 INCH W X 4.88 INCH D X 14.6 INCH H; APPROVAL UL, CSA; H MODEL

Show all:  Fusible Heavy Duty Safety Switches

 Spec Sheet   |   More Details
IN STOCK
SAFETY SWITCH
SQUARE D/TELEMECANIQUE
DU321
30A-240V-3P SW
GENERAL DUTY SAFETY; 240 V AC VOLTAGE; 30 AMPERE CURRENT RATING; POWER RATING 3 HP AT 240 VAC 1 PHASE, 7 1/2 HP AT 240 VAC 3 PHASE (MAXIMUM); 3 POLE; 3 WIRE; NON FUSIBLE FUSE; NO NEUTRAL; NEMA 1 ENCLOSURE; SIZE 7.25 INCH W X 3.63 INCH D X 9.25 INCH H; APPROVAL UL; DU MODEL

Show all:  Non-Fusible General Duty Safety Switches

 Spec Sheet   |   More Details
IN STOCK
SAFETY SWITCH
SQUARE D/TELEMECANIQUE
HU362
60A-600V-3P SW
HEAVY DUTY SAFETY; 600 V AC VOLTAGE; 250/600 V DC VOLTAGE; 60 AMPERE CURRENT RATING; POWER RATING 10 HP AT 240 VAC 1 PHASE, 20 HP AT 240 VAC 3 PHASE, 25 HP AT 480 VAC 1 PHASE, 50 HP AT 480 VAC 3 PHASE, 30 HP AT 600 VAC 1 PHASE, 60 HP AT 600 VAC 3 PHASE (MAXIMUM); 10 HP AT 250 VDC, 30 HP AT 600 VDC; 3 POLE; 3 WIRE; NON FUSIBLE FUSE; SOLID NEUTRAL; NEMA 1 ENCLOSURE; STEEL ENCLOSURE; SIZE 10.5 INCH W X 6.38 INCH D X 17.5 INCH H; APPROVAL UL, CSA; HU MODEL

Show all:  Non-Fusible Heavy Duty Safety Switches

 Spec Sheet   |   More Details
IN STOCK
SAFETY SWITCH
SQUARE D/TELEMECANIQUE
H363
100A-600V-3P SW
HEAVY DUTY SAFETY; 600 V AC VOLTAGE; 600 V DC VOLTAGE; 100 AMPERE CURRENT RATING; POWER RATING 10 HP AT 480 VAC 1 PHASE, 25 HP AT 480 VAC 3 PHASE, 30 HP AT 600 VAC 3 PHASE (STANDARD); 30 HP AT 480 VAC 1 PHASE, 60 HP AT 480 VAC 3 PHASE, 75 HP AT 600 VAC 3 PHASE (MAXIMUM); 50 HP AT 600 VDC; 3 POLE; 3 WIRE; CLASS R FUSE; FUSIBLE FUSE; SOLID NEUTRAL; NEMA 1 ENCLOSURE; STEEL ENCLOSURE; SIZE 10.5 INCH W X 6.38 INCH D X 21.25 INCH H; APPROVAL UL, CSA; H MODEL

Show all:  Fusible Heavy Duty Safety Switches

 Spec Sheet   |   More Details
IN STOCK
SAFETY SWITCH
SQUARE D/TELEMECANIQUE
DU221RB
30A-240V-2P RT SW
GENERAL DUTY SAFETY; 240 V AC VOLTAGE; 30 AMPERE CURRENT RATING; POWER RATING 3 HP AT 240 VAC 1 PHASE (MAXIMUM); 2 POLE; 2 WIRE; NON FUSIBLE FUSE; NO NEUTRAL; NEMA 3R ENCLOSURE; STEEL ENCLOSURE; SIZE 7.75 INCH W X 3.75 INCH D X 9.63 INCH H; APPROVAL UL, CSA; DU MODEL; WITH RAIN PROOF BOLT ON HUB

Show all:  Non-Fusible General Duty Safety Switches

 Spec Sheet   |   More Details
IN STOCK
SAFETY SWITCH
SQUARE D/TELEMECANIQUE
H362
60A-600V-3P SW
HEAVY DUTY SAFETY; 600 V AC VOLTAGE; 600 V DC VOLTAGE; 60 AMPERE CURRENT RATING; POWER RATING 5 HP AT 480 VAC 1 PHASE, 15 HP AT 480/600 VAC 3 PHASE (STANDARD); 20 HP AT 480 VAC 1 PHASE, 30 HP AT 480 VAC 3 PHASE, 50 HP AT 600 VAC 3 PHASE (MAXIMUM); 30 HP AT 600 VDC; 3 POLE; 3 WIRE; CLASS R FUSE; FUSIBLE FUSE; SOLID NEUTRAL; NEMA 1 ENCLOSURE; STEEL ENCLOSURE; SIZE 10.5 INCH W X 6.38 INCH D X 17.5 INCH H; APPROVAL UL, CSA; H MODEL

Show all:  Fusible Heavy Duty Safety Switches

 Spec Sheet   |   More Details
IN STOCK
SAFETY SWITCH
SQUARE D/TELEMECANIQUE
H361RB
30A-600V-3P RT SW
HEAVY DUTY SAFETY; 600 V AC VOLTAGE; 250/600 V DC VOLTAGE; 30 AMPERE CURRENT RATING; POWER RATING 3 HP AT 480 VAC 1 PHASE, 5 HP AT 480 VAC 3 PHASE, 7 1/2 HP AT 600 VAC 3 PHASE (STANDARD); 7 1/2 HP AT 480 VAC 1 PHASE, 15 HP AT 480 VAC 3 PHASE, 20 HP AT 600 VAC 3 PHASE (MAXIMUM); 5 HP AT 250 VDC, 15 HP AT 600 VDC; 3 POLE; 3 WIRE; CLASS R FUSE; FUSIBLE FUSE; SOLID NEUTRAL; NEMA 3R ENCLOSURE; STEEL ENCLOSURE; GALVANIZED FINISH; SIZE 7.55 INCH W X 4.88 INCH D X 14.88 INCH H; APPROVAL UL, CSA; H MODEL; WITH RAIN PROOF BOLT ON HUB

Show all:  Fusible Heavy Duty Safety Switches

 Spec Sheet   |   More Details
IN STOCK
SAFETY SWITCH
SQUARE D/TELEMECANIQUE
D221NRB
30A-240V-3SN RT SW
GENERAL DUTY SAFETY; 240 V AC VOLTAGE; 30 AMPERE CURRENT RATING; POWER RATING 1 1/2 HP AT 240 VAC 1 PHASE, 3 HP AT 240 VAC 3 PHASE (FAST ACTING ONE TIME FUSE); 3 HP AT 240 VAC 1 PHASE, 7 1/2 HP AT 240 VAC 3 PHASE (DUAL ELEMENT TIME DELAY FUSE); 2 POLE; 3 WIRE; CARTRIDGE, CLASS R FUSE; FUSIBLE FUSE; SOLID NEUTRAL; NEMA 3R ENCLOSURE; STEEL ENCLOSURE; GALVANIZED FINISH; SIZE 7.75 INCH W X 3.75 INCH D X 9.63 INCH H; APPROVAL UL, CSA; D MODEL; WITH FACTORY INSTALLED NEUTRAL KIT, RAIN PROOF BOLT ON HUB

Show all:  Fusible General Duty Safety Switches

 Spec Sheet   |   More Details
IN STOCK
SAFETY SWITCH
SQUARE D/TELEMECANIQUE
DU321RB
30A-240V-3P RT SW
GENERAL DUTY SAFETY; 240 V AC VOLTAGE; 30 AMPERE CURRENT RATING; POWER RATING 3 HP AT 240 VAC 1 PHASE, 7 1/2 HP AT 240 VAC 3 PHASE (MAXIMUM); 3 POLE; 3 WIRE; NON FUSIBLE FUSE; NO NEUTRAL; NEMA 3R ENCLOSURE; SIZE 7.75 INCH W X 3.75 INCH D X 9.63 INCH H; APPROVAL UL; DU MODEL; WITH RAIN PROOF BOLT ON HUB

Show all:  Non-Fusible General Duty Safety Switches

 Spec Sheet   |   More Details
IN STOCK
SAFETY SWITCH
SQUARE D/TELEMECANIQUE
HU361RB
30A-600V-3P SW
HEAVY DUTY SAFETY; 600 V AC VOLTAGE; 250/600 V DC VOLTAGE; 30 AMPERE CURRENT RATING; POWER RATING 5 HP AT 240 VAC 1 PHASE, 10 HP AT 240 VAC 3 PHASE, 7 1/2 HP AT 480 VAC 1 PHASE, 20 HP AT 480 VAC 3 PHASE, 10 HP AT 600 VAC 1 PHASE, 30 HP AT 600 VAC 3 PHASE (MAXIMUM); 5 HP AT 250 VDC, 15 HP AT 600 VDC; 3 POLE; 3 WIRE; NON FUSIBLE FUSE; SOLID NEUTRAL; NEMA 3R ENCLOSURE; STEEL ENCLOSURE; GALVANIZED FINISH; SIZE 7.55 INCH W X 4.88 INCH D X 14.88 INCH H; APPROVAL UL, CSA; HU MODEL; WITH RAIN PROOF BOLT ON HUB

Show all:  Non-Fusible Heavy Duty Safety Switches

 Spec Sheet   |   More Details
IN STOCK
* E=Each, C=100, M=1000
First Previous  Page   of  6  Next Last
 
 